Rentgeno aparatas (115 V, 50/60 Hz)
Rentgeno aparatas (115 V, 50/60 Hz)
Kodas: 3B Scientific 1000660Kaina 887777 € su PVMPrekę turime sandėlyje. Užsakius ir apmokėjus šiandien iki 14 val., pristatytume kitą darbo dieną.
Šiuo metu prekės nėra sandėlyje. Numatomas pristatymo laikas nurodytas žemiau.
Pateikus užsakymą, susisieksime su Jumis ir informuosime apie tikslų numatomą užsakymo pristatymo laiką.
GamintojasPristatymo laikas3-6 savaitės-
Informacija apie prekę Prekės kodas 1000660 [U192001-US] Svoris9 kg Ženklas 3B Scientific X-Ray Apparatus (115 V, 50/60 Hz)
The experiment chamber is contained in a closed, radiation-proof housing with a transparent synthetic-glass shield. If the synthetic-glass shield is opened, the high-voltage source for the X-ray tube is deactivated automatically. The high-vacuum X-ray tube with a directly heated tungsten cathode and copper anode is positioned in a borosilicate glass chamber with a thinwalled, concave ray emission window. A lead-glass hood with a collimator causes X-rays to emerge in parallel with the experiment plane and provides a shield against scattered radiation. The horizontal counter-tube goniometer consists of a central sample holder and a swiveling arm. In the form of a slide tray, this arm serves as a mount for the Geiger-Müller tube (U19201), ionization chamber (U19208) as well as experimental devices in slide format or on a 5 cm x 5 cm base plate (for example, from U19205, U19206, U19207). The swiveling arm can be rotated manually independently of the sample holder, or at a fixed mutual angle with a ratio of 2:1, for instance, for experiments involving Bragg’s reflection. The device is equipped with angle and millimeter scales, position markings for experimental devices, as well as radiation-proof bushings for cables and hoses. Anode voltage: 20/30 kV, switchable and electronically stabilized Emission current: 0 to 80 μA, continuously adjustable and electronically stabilized Cathode heating: 4 V, 1 A Focal spot: 5x1 mm2 Anode material: Cu Lead-glass collimator: radiation emission aperture with 5-mm dia. Ray divergence: better than 10° Characteristic radiation wavelength: Cu -Kα: 154 pm, Cu -Kβ: 138 pm Counter-tube goniometer: Swiveling ranges: 0°, +10° to +130° and -10° to +130° relative to the ray axis Angular coupling: independent of the sample holder or with a ratio of 2:1 Measurement accuracy of Bragg’s angle: 5 arc minutes Timer: 0 to 55 minutes, continuously adjustable Power consumption: 100 VA Dimensions: X-Ray apparatus: approx. 250 mm x 370 mm dia. X-Ray tube: approx. 100 mm x 32 mm dia. Weight: approx. 9 kg